xx237

Ch1 SendCurr Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Transmitter current critical (dirt, broken transmitter)

xx238

Ch1 EncTemp Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Encoder temperature critical

xx239

Ch1 Speed Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Speed too high, no position formation possible

xx240

Ch1 General Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - An error
bit of the BiSS Single Cycle Data is set

xx246

Ch1 LED Curr Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - LED
current out of control range

xx247

Ch1 ExMulTurnErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - External
multiturn error

xx248

Ch1 PsnCode Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - Position
code error (single step error)

xx249

Ch1 Config Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - failure
configuring interface

xx250

Ch1 PsnVal Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - Position
data not valid

xx251

Ch1 SerialComErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - Serial
interface failure

xx252

Ch1 Ext Failure

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface - External
failure over NERR

xx253

Ch1 Temp Exc Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by a Encoder on Channel 1 with BiSS Interface -
Temperature out of defined range

xx256

Ch1 OutOfRailErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Rail is no longer
present between the read head

xx260

Ch1 Read Head 1

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Indicates that the
read head must be cleaned or installed correctly

xx261

Ch1 Read Head 2

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Indicates that the
read head must be cleaned or installed correctly

xx262

Ch1 RAM Error

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Indicates a RAM
error. Reading head needs to be repaired

xx263

Ch1 EPROM Error

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Indicates a
EPROM error. Reading head needs to be repaired

xx264

Ch1 ROM Error

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Indicates a ROM
error. Reading head needs to be repaired

xx266

Ch1 No Position

Configurable

P39
[FB1 Loss Cfg]

Error reported by a linear Stahl encoder on Channel 1 - Indicates that no
position value was available - only possible following powerup or reset

xx281

Ch1 Msg Cheksum

Configurable

P39
[FB1 Loss Cfg]

Indicates the option card has detected a serial communications
checksum error while attempting to communicate with the encoder on
channel 1.

xx282

Ch1 Timeout

Configurable

P39
[FB1 Loss Cfg]

Indicates the option card has detected a serial communications timeout
error while attempting to communicate with the encoder on channel 1.

xx283

Ch1 Comm

Configurable

P39
[FB1 Loss Cfg]

Indicates the option card has detected a serial communications error
(other than checksum or timeout) while attempting to communicate
with the encoder on channel 1.

xx284

Ch1 Diagnostic

Configurable

P39
[FB1 Loss Cfg]

Indicates the option card has detected a powerup diagnostic test failure
for encoder channel 1.

xx285

Ch1 SpplyVltgRng

Configurable

P39
[FB1 Loss Cfg]

Indicates that the voltage source to the encoder 1 is out of range.

Event
No.

(1)

Fault/Alarm Text

Type

Fault
Action

Configuration Param

Auto
Reset

Description