Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 166

Advertising
background image

166

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 3

Drive Port 0 Parameters

DIA

G

NOSTICS

Fa

u

lt

/A

la

rm

In

fo

960

Alarm Status B
Alarm Status B

RO

32-bit
Integer

Indicates the occurrence of conditions that have been configured as alarms.

Bit 0 “IGBT OT” – Indicates the transistor (IGBT) junction temperature reached the alarm level, which is 10 °C (50 °F) below the maximum (fault level) junction
temperature.
Bit 1 Heatsink OT” – Indicates the heatsink temperature reached the alarm level, which is 10 °C (50 °F) below the maximum (fault level) heatsink temperature.
Bit 2 “Waking” – The Sleep /Wake function is in the Waking condition.
Bit 3 “StartOnPwrUp” – The Start on powerup feature is active.
Bit 4 “Drive OL” – Indicates overload condition has reached the alarm level and P940 [Drive OL Count] has reached 50%.
Bit 5 “CurLmt Reduc” – Indicates the transistor (IGBT) junction temperature reached the level of current limit fold back, which is 5 °C (41 °F) below the maximum
(fault level) junction temperature.
Bit 6 “PWMFrq Reduc” – Indicates the transistor (IGBT) junction temperature reached the level of PWM frequency fold back, which is 10 °C (50 °F) below the
maximum (fault level) junction temperature. Or the instantaneous rising of junction temperature exceeded 60 °C (140 °F).
Bit 7 “Profile Actv” – Indicates the profile function is active, P1213 [Profile Command] Bit 12 “Prof Run Alarm” is set.
Bit 8 “Homing Actv” – Indicates the homing function is active, P731 [Homing Control] Bit 5 “Homing Alarm” is set.
Bit 9 “Not Home Set” – Indicates the profile function has executed without first executing the homing function, P1213 [Profile Command] Bit 11
“HomeNotSetAlarm” is set.
Bit 10 “Gnd Warning” – The value set in P467 [Ground Warn Lvl] has been exceeded.
Bit 11 “OW Level” – The value set in P1171 [TorqAlarm Level] has been reached.
Bit 12 “OW Alarm TO” – The value set in P1172 [TorqAlm Timeout] has been reached.
Bit 13 “PumpOff Alrm” – The pump off condition is active.
Bit 14 “N-1 Operate” – Indicates the parallel drive is in operation mode.
Bit 15 “DB Res OT” – Indicates the dynamic brake resistor has exceeded its maximum operating temperature.

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

DB

Re

s O

T

N-1 O

perat

e

(1

)

(1) 755 Frame 8 drives and larger only.

Pu

mpO

ff Alrm

(2

)

OW

Al

ar

m

T

O

(2)

OW

Le

ve

l

(2)

(2) 753 drives only.

Gnd W

arning

Not Home S

et

(3

)

Ho

m

in

g Ac

tv

Pr

ofi

le

Ac

tv

(3)

(3) 755 drives only.

PW

MF

rq

Reduc

Cu

rL

m

t R

ed

uc

Driv

e OL

St

ar

tO

nP

w

rUp

Wa

ki

ng

He

at

si

nk

O

T

IG

BT O

T

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True