Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 254

254
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 5
Embedded Feature and Option Module Parameters
11
-Serie
s I/O
An
al
og O
u
tpu
ts
82
Anlg Out0 Val
Analog Output 0 Value
Displays the analog output value.
Units:
Default:
Min/Max:
Volt
mA
10.000 Volts
20.000 mA
–/+10.000 Volts
0.000 / 20.000 mA
RO
Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Rea
d-Write
Da
ta T
ype
11-S
eries I/O
Pr
edi
ct
iv
e Mai
n
99
PredMaint Sts
Predictive Maintenance Status
RO
16-bit
Integer
Status of relay’s predictive maintenance.
(1) Bit 1= “Relay Out 0” for 11-Series I/O Module models 20-750-1132C-2R and 20-750-1132D-2R
100
RO0 Load Type
Relay Output 0 Load Type
Sets the type of load that will be applied to the relay. Must be properly set for the
Predictive Maintenance function to predict the relay life.
Default:
Options:
1 = “DC Inductive”
0 = “DC Resistive”
1 = “DC Inductive”
2 = “AC Resistive”
3 = “AC Inductive”
RW 32-bit
Integer
101
RO0 Load Amps
Relay Output 0 Load Amps
Load current that will be applied to the relay contacts. Must be properly set for the
Predictive Maintenance function to approximate the relay life.
Units:
Default:
Min/Max:
Amps
2.000
0.000 / 2.000
RW Real
102
RO0 TotalLife
Relay Output 0 Total Life
Total life cycles of the relay based on programmed load type and amps.
Units:
Default:
Min/Max:
Cycl
0
0 / 2147483647
RO
32-bit
Integer
103
RO0 ElapsedLife
Relay Output 0 Elapsed Life
Non-resettable, total accumulated cycles of the relay.
Units:
Default:
Min/Max:
Cycl
0
0 / 2147483647
RO
32-bit
Integer
104
RO0 RemainLife
Relay Output 0 Remaining Life
The difference between the Total Life and the Elapsed Life.
Units:
Default:
Min/Max:
Cycl
0
0 / 2147483647
RO
32-bit
Integer
105
RO0 LifeEvntLvl
Relay Output 0 Life Event Level
Sets the percentage of relay life cycles before action is taken.
Units:
Default:
Min/Max:
%
80.000
0.000 / 100.000
RW Real
Options
Mast
er
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
la
y Out
0
(1)
Re
la
y Out
0
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = Condition False
1 = Condition True