Drive Port 0 Parameters

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

POSITION C

O

N

TR

O

L

Po

si

ti

on R

eg

830

PsnNtchFltrFreq
Position Notch Filter Frequency
Sets the center frequency of the position notch filter.

Units:
Default:
Min/Max:

Hz
0.00
0.00 / 500.00

RW Real

831

PsnNtchFltrDepth
Position Notch Filter Depth
Sets the depth for the position notch filter. Attenuation is the ratio of the output to the
input at the notch frequency P830 [PsnNtchFltrFreq]. The attenuation of 30 means that
the notch output is 1/30th of the input at the specified frequency.
Calculation: Attenuation = Input / Output

Default:
Min/Max:

50.00
0.00 / 500.00

RW Real

832

Psn Out Fltr Sel
Position Output Filter Select
Selects a type of lead-lag filter for position regulator speed output. This parameter sets
filter gain P833 [Psn Out FltrGain] and bandwidth P834 [Psn Out Fltr BW] according to
the selected type.
“Off” (0) – P833 = 1.000, P834 = 0.00
“Custom” (1) – P833 = user setting, P834 = user setting

Default:
Options:

0 = “Off”
0 = “Off”
1 = “Custom”

RW 32-bit

Integer

833

Psn Out FltrGain
Position Output Filter Gain
Sets lead-lag filter gain. A default value is sets when the filter type selection P832 [Psn
Out Fltr Sel] is not Custom (Option 1). See the filter type selection P832.

Default:
Min/Max:

3.000
–/+5.000

RW Real

834

Psn Out Fltr BW
Position Output Filter Bandwidth
Sets lead-lag bandwidth. A default value is sets when the filter type selection P832 [Psn
Out Fltr Sel] is not Custom (Option 1). See the filter type selection P832.

Units:
Default:
Min/Max:

R/S
50.00
0.00 / 500.00

RW Real

835

Psn Error
Position Error
Indicates actual position error in motor pulse counts as a 32-bit integer. When the
position regulator is not enabled, the value is initialized to zero. When the position
regulator is enabled, the value contains the running value of position error between the
position command P723 [Psn Command] and P836 [Psn Actual].

Default:
Min/Max:

0
–2147483648 / 2147483647

RO

32-bit
Integer

836

Psn Actual
Position Actual
Indicates accumulated motor position as a 32-bit integer. It tracks the position feedback
P847 [Psn Fdbk]. When P721 [Position Control] Bit 4 “Zero Psn” is set, this parameter
accumulates the value of P847 [Psn Fdbk] - the P725 [Zero Position]. When P721
[Position Control] Bit 4 “Zero Psn” is off, this parameter accumulates the value of P847
[Psn Fdbk].

Default:
Min/Max:

0
–2147483648 / 2147483647

RO