Drive Port 0 Parameters

Chapter 3

APPLIC

AT

IO

NS

Camm

ing

1395

PCAM PsnOfst Eps

Position Camming Position Offset Eps
The parameter provides count of edges per second for virtual encoder function. The
value makes a limit on change of x-axis position in change of position offset input.

Default:
Min/Max:

2000
0 / 2147483647

RW 32-bit

Integer

1396

PCAM Span X

Position Camming Span X Axis
The parameter provides the number of integer counts equivalent to the span or range of
x-axis.

Default:
Min/Max:

8192
0 / 2147483647

RW 32-bit

Integer

1397

PCAM Scale X

Position Camming Scale X Axis
The parameter multiplies span x (P1396 [PCAM Span X]) such that the x-axis dimension
will expand if this parameter is greater than 1.

Default:
Min/Max:

1.00
0.01 / 214748000.00

RW Real

1398

PCAM Span Y

Position Camming Span Y Axis
The parameter provides the number of edges equivalent to the span of the y-axis. The
value is the number of integer counts representing the maximum vertical extent of the
profile.

Default:
Min/Max:

8192
0 / 2147483647

RW 32-bit

Integer

1399

PCAM ScaleY Sel

Position Camming Scale Y Axis Select
The parameter selects a source for y-axis scale.

Default:
Options:

1400
1 / 159999

RW 32-bit

Integer

1400

PCAM ScaleYSetPt

Position Camming Scale Y Axis Setpoint
The parameter provides y-axis scale when the y scale select (P1399 [PCAM ScaleY Sel])
selects this parameter. The y scale multiplies the y span such that the y-axis dimension
will increase if y scale is greater than 1.

Default:
Min/Max:

1.00
0.00 / 214748000.00

RW Real

1401

PCAM VelScaleSel

Position Camming Velocity Scale Select
The parameter selects a source for velocity scale.

Default:
Options:

1402
1 / 159999

RW 32-bit

Integer

1402

PCAM VelScaleSP

Position Camming Velocity Scale Setpoint
The parameter provides velocity scale when the velocity scale select (P1401 [PCAM
VelScaleSel]) selects this parameter. The velocity scale multiplies the velocity output
(P1472 [PCAM Vel Out]) such that the velocity output (P1472) will decrease if the
velocity scale is less than 1.

Units:
Default:
Min/Max:

MPE
0.000100
0.000000 / 8.000000

RW Real

1403

PCAM Slope Begin

Position Camming Slope Begin
The parameter provides beginning slope at CAM point 0. The parameter is used only if
the segment is cubic type curve.

Default:
Min/Max:

0.00
–/+214748000.00

RW Real

1404

PCAM Slope End

Position Camming Slope End
The parameter provides ending slope at CAM point 0. The parameter is used only if the
segment is cubic type curve in both the main and the auxiliary CAM profile.

Default:
Min/Max:

0.00
–/+214748000.00

RW Real

1405

PCAM Main EndPnt

Position Camming Main End Point
The parameter provides a number of the last CAM point used in the main CAM profile.

Default:
Options:

0
0 / 15

RW 32-bit

Integer

Fi