Inverter (Port 10) Common
Parameters

Inverter Common parameters apply only to PowerFlex 755 Frame 8 and larger
drives.

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta

T

yp

e

IN

VE

R

TER

C

O

MM

O

N

Sy

st

em

Ra

tings

1

Sys Rated Amps

System Rated Amps
Displays the continuous current rating of the drive. This parameter is the same value as
displayed in P21 [Rated Amps] for the drive at Port 0.

Units:
Default:
Min/Max:

Amps
0.00
0.00 / 5000.00

RO

Real

2

Sys Rated Volts

System Rated Volts
Input voltage class (400, 480, 600, 690, etc) of the drive. This parameter is the same
value as displayed in P20 [Rated Volts] for the drive at Port 0.

Units:
Default:
Min/Max:

V AC
0.00
0.00 / 690.00

RO

Real

3
4
5

I1 Rated Amps
I2 Rated Amps
I3 Rated Amps

Inverter n Rated Amps
Continuous current rating of inverter n. The continuous current rating varies based on
the value of P305 [Voltage Class] and P306 [Duty Rating] for the drive at Port 0.

Units:
Default:
Min/Max:

Amps
0.00
0.00 / 1000.00

RO

Real

21

Effctv I Rating

Effective Inverter Rating
Sets the effective inverter current rating. During N-1 operation, the effective inverter
current rating is reduced from P21 [Rated Amps].

Units:
Default:
Min/Max:

Amps
0.0
0.0 / 5000.0

RO

Real

755 (8+)

755 (8+)

755 (8+)
755 (8+)
755 (8+)

755 (8+)

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Read-W

ri

te

Da

ta

T

yp

e

IN

VERTER C

O

MMON

Sta

tus

10

Online Status

Online Status

RO

16-bit
Integer

Indicates whether the inverter has successfully established fiber optic communications with the main control board.

12

Fault Status

Fault Status

RO

16-bit
Integer

Indicates whether the inverter has a fault condition. See P105 [I1 Fault Status] to view which fault conditions currently exist for inverter 1. Refer to

Chapter 6

for

information on fault and alarm codes.

755 (8+)

Options

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

In

ve

rt

er 2

In

ve

rt

er 1

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Not Active
1 = Active

755 (8+)

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

In

ve

rt

er 2

In

ve

rt

er 1

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Not Faulted
1 = Faulted