Rockwell Automation Publication 750-PM001J-EN-P - October 2014

181

Drive Port 0 Parameters

Chapter 3

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

AP

PL

IC

AT

IONS

Pump Jac

k

1165

Rod Speed
Rod Speed
Displays the speed in RPM of the pump rod after the gearbox and sheaves.
Rod Speed = Motor Speed x P1174 [Total Gear Ratio]

Units:
Default:
Min/Max:

RPM
0.00
0.00 / 10000.00

RO

Real

1166

Rod Torque
Rod Torque
Displays the load side torque. P1174 [Total Gear Ratio] must be greater than zero to
activate this display.

Units:
Default:
Min/Max:

FtLb
0.00
0.00 / 10000.00

RO

Real

1167

Rod Speed Cmd
Rod Speed Command
Displays the commanded speed in RPM of the pump rod after the gearbox and sheaves.

Units:
Default:
Min/Max:

RPM
0.00
0.00 / 10000.00

RO

Real

1168

TorqAlarm Action
Torque Alarm Action
Sets the drive action when the Torque Alarm is exceeded. Note: only active with PC
pump applications. See P1179 [OilWell Pump Cfg].

Default:
Options:

0 = “Ignore”
0 = “Ignore”
1 = “Preset Spd1”

RW 32-bit

Integer

1169

TorqAlarm Config
Torque Alarm Configure

RW 16-bit

Integer

Enables the Torque Alarm function.

1170

TorqAlarm Dwell
Torque Alarm Dwell
Sets the time that the torque must exceed P1171 [TorqAlarm Level] before P1168
[TorqAlarm Action] takes place.
Active when P1169 [TorqAlarm Config] Bit 0 “Torque Level” = 1 (enabled).

Units:
Default:
Min/Max:

Secs
0.0
0.0 / 60.0

RW Real

1171

TorqAlarm Level
Torque Alarm Level
Sets the level at which the Torque Alarm becomes active.
Active when P1169 [TorqAlarm Config] Bit 0 “Torque Level” = 1 (enabled)

Units:
Default:
Min/Max:

FtLb
0.0
0.0 / 5000.0

RW Real

1172

TorqAlm Timeout
Torque Alarm Time Out
Sets the amount of time a Torque Alarm can be active until timeout action begins.
Active when P1169 [TorqAlarm Config] Bit 0 “Torque Level” = 1 (enabled)

Units:
Default:
Min/Max:

Secs
0.0
0.0 / 600.0

RW Real

1173

TorqAlarm TOActn
Torque Alarm Time Out Action
Sets the drive action when P1172 [TorqAlrm Timeout] is exceeded.
Active when P1169 [TorqAlarm Config] Bit 0 “Torque Level” = 1 (enabled)
“Ignore” (0) – No action is taken.
“Alarm” (1) – Type 1 alarm indicated.
“Flt Minor” (2) – Minor fault indicated. If running, drive continues to run.
Enable with P950 [Minor Flt Cfg]. If not enabled, acts like a major fault.
“FltCoastStop” (3) – Major fault indicated. Coast to Stop.
“Flt RampStop” (4) – Major fault indicated. Ramp to Stop.
“Flt CL Stop” (5) – Major fault indicated. Current Limit Stop.

Default:
Options:

0 = “Ignore”
0 = “Ignore”
1 = “Alarm”
2 = “Flt Minor”
3 = “FltCoastStop”
4 = “Flt RampStop”
5 = “Flt CL Stop”
6 = “Resume”

RW 32-bit

Integer

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

To

rq

ue

L

ev

el

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Disabled
1 = Enabled