Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 204

Advertising
background image

204

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 3

Drive Port 0 Parameters

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

APPLIC

AT

ION

S

Va

ri

ab

le

B

oo

st

1535

VB Config
Variable Boost Configuration

RO

16-bit
Integer

Controls the variable boost function.

Bit 0 “VB Enable” – Enables the variable boost voltage function.
Bit 1 “Current Rate” – The current rate trigger condition is defined by the level set in P1550 [VB Cur Thresh] with a hysteresis band of P1549 [VB Current Hyst]. The
slope of P1548 [VB Current Rate] is set to either default falling edge or rising edge by Bit 2 “Rising Edge.” If these trigger conditions are met, P1536 [VB Status] Bit 3
“Current Trig” is set.
Bit 2 “Rising Edge” – The current rate trigger condition is defined by the level set in P1550 [VB Cur Thresh] with a hysteresis band of 1549 [VB Current Hyst]. The
slope of P1548 [VB Current Rate] is set to either default falling edge or rising edge by Bit 2 “Rising Edge.” If these trigger conditions are met, P1536 [VB Status] Bit 3
“Current Trig” is set.
Bit 3 “Flux Level” – Sets the flux trigger condition defined by the level of P1545 [VB Flux Thresh]. If P1547 [VB Filt Flux Cur] is greater than or equal to P1545 [VB
Flux Thresh], P1536 [VB Status] Bit 4 “Flux Trigger” is set.
Bit 4 “Minimum Freq” – Sets the minimum frequency trigger source derived from P1 [Output Frequency] and is enabled by setting P1535 [VB Config] Bit 4
“Minimum Freq.” If P1 [Output Frequency] is less than or equal to P1544 [VB Min Freq], P1536 [VB Status] Bit 5 “Freq Trigger” is set.

1536

VB Status
Variable Boost Status

RO

16-bit
Integer

Status bits for the variable boost function.

Bit 0 “VB Enabled” – The variable boost voltage function is enabled.
Bit 1 “VB Timer” – P1538 [VB Time] has expired.
Bit 2 “Triggered” – Indicates that a trigger function has been enabled by 1535 [VB Config].
Bit 3 “Current Trig” – This trigger condition is defined by P1550 [VB Cur Thresh] with a hysteresis band of P1549 [VB Current Hyst]. The slope of P1548 [VB Current
Rate] is set to either default falling edge or rising edge by P1535 [VB Config] Bit 2 “Rising Edge.” If these trigger conditions are met, this bit is set.
Bit 4 “Flux Trigger” – This trigger event is enabled by P1535 [VB Config] Bit 3 “Flux Level.” The trigger condition is defined by the level P1545 [VB Flux Thresh]. If
P1547 [VB Filt Flux Cur] is greater than or equal to P1545 [VB Flux Thresh], P1536 [VB Status] Bit 4 “Flux Trigger” is set.
Bit 5 “Freq Trigger” – This trigger event is enabled when P1 [Output Frequency] is less than or equal to P1544 [VB Min Freq].
Bit 6 “Max Boost” – This trigger event is enabled when P1537 [VB Voltage] reaches P1540 [VB Maximum] before any of the other trigger events cause P1537 [VB
Voltage] to ramp down.
Bit 7 “Hold Freq” – Output frequency is being held at P1543 [VB Frequency].

1537

VB Voltage
Variable Boost Voltage
Displays the output value of the voltage-axis intercept of the V/Hz curve.
When the variable boost function is enabled, the value of [VB Voltage] is ramped up/
down according to the settings of the variable boost function when the drive is running.
This parameter is equal to P60 [Start Acc Boost] and P61 [Run Boost] when the drive is
stopped or when P1535 [VB Config] Bit 0 “VB Enable” = 0.

Units:
Default:
Min/Max:

V AC
0.0
0.0 / 460.0

RO

Real

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Minimum F

req

Fl

ux

L

eve

l

Ris

in

g E

dge

Cu

rr

en

t R

at

e

VB E

nable

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Disabled
1 = Enabled

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Ho

ld

Fre

q

M

ax B

oost

Fr

eq T

rigger

Fl

ux T

rigger

Cu

rr

en

t T

rig

Tr

igger

ed

VB T

im

er

VB E

nabled

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True

Advertising