Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 169

Advertising
background image

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

169

Drive Port 0 Parameters

Chapter 3

964

See

page 212

.

Fi

le

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

DIA

G

NOSTICS

Te

st

po

in

ts

970
974
978
982

Testpoint Sel 1
Testpoint Sel 2
Testpoint Sel 3
Testpoint Sel 4
Testpoint Select n
Selects a source for the testpoint values (“Fval” and “Lval”). Used by the factory, typically
for diagnostic purposes.

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

971
975
979
983

Testpoint Fval 1
Testpoint Fval 2
Testpoint Fval 3
Testpoint Fval 4
Testpoint Float Value n
Displays data selected by [Testpoint Sel n], if the data type is floating point.

Default:
Min/Max:

0.000000
–/+ 220000000.000000

RW Real

972
976
980
984

Testpoint Lval 1
Testpoint Lval 2
Testpoint Lval 3
Testpoint Lval 4
Testpoint Long Value n
Displays data selected by [Testpoint Sel n], if the data type is long integer.

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta

T

yp

e

DIA

G

NOSTICS

Pe

ak

D

et

ec

ti

on

1035

PkDtct Stpt Real

Peak Detection Setpoint Real
A setpoint value, in the form of a real number. Intended to be used as a potential data
source for P1038 [PkDtct1PresetSel] and P1043 [PkDtct2PresetSel].

Default:
Min/Max:

0.000000
–/+ 220000000.000000

RW Real

1036

PkDtct Stpt DInt

Peak Detection Setpoint D Integer
A setpoint value, in the form of an integer number. Intended to be used as a potential
data source for P1038 [PkDtct1PresetSel] and P1043 [PkDtct2PresetSel].

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

1037

PkDtct1 In Sel

Peak Detection 1 Input Select
Selects the input data source for the peak detect functions. The functions can be
configured to sample and hold either the largest (maximum) or smallest (minimum)
value of the input signal selected by this parameter.
Important: Either real or integer data sources can be selected, but integer sources will
be internally converted to real and displayed in the peak detect output as real numbers.

Default:
Min/Max:

1035
0 / 15999931

RW 32-bit

Integer

1038

PkDtct1PresetSel

Peak Detection 1 Preset Select
Selects the preset data source for the peak detect functions. The output of the each peak
detect function can be forced to equal the value of the input signal selected by this
parameter by using the”Peak1 Set” bit in P1039 [Peak1 Cfg]. The same integer to real
number conversion applies to both the input and the preset signal.

Default:
Min/Max:

0
0 / 15999931

RW 32-bit

Integer

755

755

755

755