Drive (Port 0) Cfg File

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

DR

IVE CFG

Pr

ef

er

en

ce

s

300

Speed Units
Speed Units
Selects the units to be used for all speed related parameters. This parameter is only reset
when Set Defaults “All” (not recommended) is executed.

Default:
Options:

Current Selection
0 = “Hz”
1 = “RPM”

RW 32-bit

Integer

301

Access Level
Access Level
Sets the access level for parameters and option choices.
“Basic” (0) – Provides the smallest, simplest, and most user friendly view.
“Advanced” (1) – May be required to use advanced features.
“Expert” (2) – Not normally recommended (makes the list very long), and shows extra
parameters that should rarely be required.
When the access level is changed, PC-based tools (for example Drive Tools and Drive
Explorer) will require a reconnect.
This parameter is only reset when Set Defaults “All” (not recommended) is executed.

Default:
Options:

Current Selection
0 = “Basic”
1 = “Advanced”
2 = “Expert”

RW 32-bit

Integer

302

Language
Language
Select display language.
This parameter is only reset when Set Defaults “All” (not recommended) is executed.

Default:
Options:

0 = “Not Selected”
0 = “Not Selected”
1 = “English”
2 = “French”
3 = “Spanish”
4 = “Italian”
5 = “German”
6 = “Japanese”
7 = “Portuguese”
8 = “Chinese”
9 = “Reserved”
10 = “Reserved”
11 = “Korean”

RW 32-bit

Integer