Rockwell Automation Publication 750-PM001J-EN-P - October 2014

515

Integrated Motion on EtherNet/IP

Appendix E

Motor Overload

There is a difference between how Kinetix handles an overload condition
compared to the PowerFlex755 drive. Kinetix is Motor Capacity whereas
PowerFlex 755 is Motor Overload.

The Motion attribute, Inverter Capacity, is a real-time estimate of the continuous
rated motor thermal capacity that is utilized during operation that is based on the
motor thermal model. A value of 100% would indicate that the motor is being
used at 100% of rated capacity as determined by the continuous current rating of
the motor.

The PowerFlex 755 parameter, P940 [Drive OL Count], indicates power unit
overload (I

2

T) in percentage. The value remains at 0 until 100% of Rated

Current is reached then the Overload measurement begins. When the value
reaches 100%, the power unit overload fault occurs.

P839

Psn Reg Kp

441

1B9

Kpp

P842

PsnReg IntgrlOut

437

1B5

Position Integrator Output

P843

PsnReg Spd Out

438

1B6

Position Loop Output

P847 Psn

Fdbk

434

1B2

Position

Feedback

P940

Drive OL Count

636

27C

Inverter Capacity
(See See

Motor Overload on page 515

)

P942

IGBT Temp C

641

281

Inverter Temperature

P944

Drive Temp C

640

280

Inverter Heatsink Temperature

Drive

Integrated Motion

Parameter No.

Parameter Name

Base 10

Base 16

Integrated Motion on EtherNet/IP Instance