Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 77

Advertising
background image

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

77

Drive Port 0 Parameters

Chapter 3

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

FEEDBA

CK & I/O

Digi

tal O

utput

s

225

Dig Out Sts

Digital Output Status

RO

16-bit
Integer

Status of the digital outputs.

226

Dig Out Invert

Digital Output Invert

RO

16-bit
Integer

Inverts the selected digital output.

227

Dig Out Setpoint

Digital Output Setpoint

RO

16-bit
Integer

Controls Relay or Transistor Outputs when chosen as the source. Can be used to control outputs from a communication device using DataLinks.

230

RO0 Sel

Relay Output 0 Select
Selects the source that will energize the relay output.
Any status parameter bit can be used as an output source. For example P935 [Drive
Status 1] Bit 7 “Faulted.”

Default:
Min/Max:

0
0 / 159999.15

RW 32-bit

Integer

231

RO0 Level Sel

Relay Output 0 Level Select
Selects the source of the level that will be compared.

Default:
Min/Max:

0
0 / 159999

RW 32-bit

Integer

232

RO0 Level

Relay Output 0 Level
Sets the level compare value.

Default:
Min/Max:

0.0
–/+1000000.0

RW Real

753

Options

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Tr

an

s O

ut

0

Re

la

y O

ut 0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True

753

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Tr

an

s O

ut

0

Re

lay O

ut

0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True

753

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Tr

an

s O

ut

0

Re

la

y Out

0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True

753

753