Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 176

176
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 3
Drive Port 0 Parameters
APPLIC
AT
IONS
To
rq
u
e P
ro
ve
1103
Trq Prove Status
Torque Prove Status
RO
16-bit
Integer
Displays the status bits for TorqProve.
Bit 0 “EndLimitActv” – End travel limit active.
Bit 1 “DecelLmtActv” – Decel travel limit active.
Bit 2 “Micro Psn” – Micro position active.
Bit 3 “BrkSlip1 Alm” – Brake slip detected.
Bit 4 “Brake Set” – Brake signal set. For example set P10 [RO0 Sel] on the digital I/O module to Port 0, P1103 Bit 4 and set P6 [Dig Out Invert] Bit 0 = 1.
Bit 5 “LoadTestActv” – The test used to check the load for above base speed operation is active.
Bit 6 “RefLoadLmted” – The reference is limited due to the load test results.
Bit 7 “Encoderless” – Encoderless configure fault is active.
1104
Trq Lmt SlewRate
Torque Limit Slew Rate
Sets the rate to ramp the torque limits to zero during brake proving.
Units:
Default:
Min/Max:
Secs
10.000
0.500 / 300.000
RW Real
1105
Speed Dev Band
Speed Deviation Band
The amount of allowable deviation between the commanded speed and the actual
speed (from a feedback device). When this value is exceeded for the amount of time in
P1106 [SpdBand Intgrtr], a fault will occur.
Units:
Default:
Min/Max:
Hz
RPM
P27 [Motor NP Hertz] x 0.0334
P28 [Motor NP RPM] x 0.0334
P27 x 0.0016 / P27 x 0.25
P28 x 0.0016 / P28 x 0.25
RW Real
1106
SpdBand Intgrtr
Speed Band Integrator
The amount of time for which the actual speed is allowed to deviate from P1105 [Speed
Dev Band] before a fault occurs.
Units:
Default:
Min/Max:
Secs
0.060
0.001 / 0.200
RW Real
1107
Brk Release Time
Brake Release Time
With an encoder, this parameter sets the time between the brake release command and
when the drive begins to accelerate.
Without an encoder, this parameter sets the time to release the brake after drive starts.
Units:
Default:
Min/Max:
Secs
0.100
0.000 / 10.000
RW Real
1108
Brk Set Time
Brake Set Time
Defines the amount of delay time between commanding the brake to be set and the
start of brake proving.
Units:
Default:
Min/Max:
Secs
0.100
0.000 / 10.000
RW Real
1109
Brk Alarm Travel
Brake Alarm Travel
Sets the number of motor shaft revolutions allowed during the brake slippage test. Drive
torque is reduced to check for brake slippage. When slippage occurs, the drive allows
this number of motor shaft revolutions before regaining control. Not used when P1100
[Trq Prove Cfg] Bit 1 “Encoderless” = 1 (enabled).
Default:
Min/Max:
1.00
0.00 / 1000.00
RW Real
1110
Brk Slip Count
Brake Slip Count
Sets the number of encoder counts to define a brake slippage condition and is based on
the feedback device attached to P135 [Position Feedback]. Not used when P1100 [Trq
Prove Cfg] Bit 1 “Encoderless” = 1 (enabled).
Default:
Min/Max:
250.00
0.00 / 65535.00
RW Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype
755
Options
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Encoder
less
Re
fL
oa
dL
m
ted
Lo
ad
Te
st
Ac
tv
Br
ak
e Se
t
Br
kSlip
1 A
lm
Mi
cr
o P
sn
Dec
el
Lm
tA
ctv
EndLimitA
ct
v
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = Disabled
1 = Enabled
755
755
755
755
755
755
755