Rockwell Automation Publication 750-PM001J-EN-P - October 2014

483

Appendix

C

Using DeviceLogix

Introduction

DeviceLogix (DLX) is an embedded component that is located in Port 14 of
PowerFlex 750-Series drives. It is used to control outputs and manage status
information locally within the drive. It can function stand-alone or
complimentary to supervisory control.

DeviceLogix programming for PowerFlex 750-Series drives is accomplished

through a DeviceLogix Editor component (

icon), which is incorporated in

the following versions of drive software:

Only the drive software tools that are listed above can be used to program the
DeviceLogix component in PowerFlex 750-Series drives. Other DeviceLogix
Editors, such as RSNetWorx for DeviceNet, cannot be used.

IMPORTANT

The Human Interface Module (HIM) CopyCat function does not work with the
following firmware versions.

PowerFlex 753 firmware version 1.005
PowerFlex 755 firmware versions 1.009 or 1.010.

Drive Software Tool

PowerFlex 755 v1.xx

PowerFlex 753 v1.xx, v5.xx
PowerFlex 755 v2.xx…v5.xx

PowerFlex 753 v6.xx…v7.xx
PowerFlex 755 v6.xx…v7.xx

DriveExplorer

v6.01 (and higher)

v6.02 (and higher)

v6.04 (and higher)

DriveTools SP / DriveExecutive

v5.01 (and higher)

v5.02 (and higher)

v5.05 (and higher)

DeviceLogix 5000 Drive Add-On
Profiles

v2.01 (and higher)

v2.02 (and higher)

v4.02 (and higher)

Connected Components
Workbench

v1.02 (and higher)

v1.02 (and higher)

v1.02 (and higher)

IMPORTANT

DeviceLogix projects that are created with PowerFlex 755 firmware versions
1.009 or 1.010 do not work with firmware version 2.002 or greater. These
projects need to be opened and adjusted in an editor (for example
DriveExplorer or DriveExecutive) before being downloaded to the drive.