Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 236

Advertising
background image

236

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 5

Embedded Feature and Option Module Parameters

Em

bedded EtherN

et/IP

51

Net Rate Act

Network Rate Actual
Displays the actual network data rate used by the adapter.

Default:
Options:

0 = “No Link”
0 = “No Link”
1 = “10Mbps Full”
2 = “10Mbps Half”
3 = “100Mbps Full”
4 = “100Mbps Half”
5 = “Dup IP Addr”

RO

32-bit
Integer

52

Web Enable

Web Enabled
Enables/disables the adapter Web page features.
For detailed information on the Web enable feature, refer to the PowerFlex 755 Drive
Embedded EtherNet/IP Adapter User Manual, publication 750COM-UM001.

Default:
Options:

0 = “Disabled”
0 = “Disabled”
1 = “Enabled”

RW 32-bit

Integer

53

Web Features

Web Features

RW 16-bit

Integer

Enables/disables the Web-configurable e-mail notification feature.
For detailed information on the Web enable feature, refer to the PowerFlex 755 Drive Embedded EtherNet/IP Adapter User Manual, publication

750COM-UM001

.

54

Comm Flt Action

Communication Fault Action
Sets the action that the adapter and drive will take if the adapter detects that I/O
communications have been disrupted. This setting is effective only if I/O that controls
the drive is transmitted through the adapter.

Default:
Options:

0 = “Fault”
0 = “Fault”
1 = “Stop”
2 = “Zero Data”
3 = “Hold Last”
4 = “Send Flt Cfg”

RW 32-bit

Integer

55

Idle Flt Action

Idle Fault Action
Sets the action that the adapter and drive will take if the adapter detects that the
controller is in program mode or faulted. This setting is effective only if I/O that controls
the drive is transmitted through the adapter.

Default:
Options:

0 = “Fault”
0 = “Fault”
1 = “Stop”
2 = “Zero Data”
3 = “Hold Last”
4 = “Send Flt Cfg”

RW 32-bit

Integer

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

755

755

755

Options

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Em

ai

l C

on

fig

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Disabled
1 = Enabled

755

ATTENTION: Risk of injury or equipment damage exists. P54 [Comm Flt Action] lets you determine the action of the
adapter and connected drive if I/O communications are disrupted. By default, this parameter faults the drive. You can set
this parameter so that the drive continues to run. Precautions should be taken to ensure that the setting of this parameter
does not create a risk of injury or equipment damage. When commissioning the drive, verify that your system responds
correctly to various situations (for example, a disconnected cable).

755

ATTENTION: Risk of injury or equipment damage exists. P55 [Idle Flt Action] lets you determine the action of the adapter
and connected drive when the controller is idle. By default, this parameter faults the drive. You can set this parameter so
that the drive continues to run. Precautions should be taken to ensure that the setting of this parameter does not create a
risk of injury or equipment damage. When commissioning the drive, verify that your system responds correctly to various
situations (for example, a controller in idle state).