Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 332

Advertising
background image

332

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 6

Troubleshooting

10131
10231
10331

I1 Fault Q Full
I2 Fault Q Full
I3 Fault Q Full

Resettable
Fault

Coast

The fault queue is full. There are at least three other faults in the queue.
Troubleshooting and clearing the existing faults will make room for
additional faults in the queue (if any).
This fault may occur during a normal power down sequence.

10132
10232
10332

I1 Incompat PS
I2 Incompat PS
I3 Incompat PS

Resettable
Fault

Coast

The drive has detected an incompatible power supply for the drive AC
input rating.

Check the power supply and replace it if incorrect.
If the power supply is correct, re-flash the control board.
If this problem persists, replace the inverter power supply board or

power layer interface board.

10134
10234
10334

I1 UBrd Fault
I2 UBrd Fault
I3 UBrd Fault

Resettable
Fault

Coast

The power supply on the U, V, or W phase gate driver board has failed.

If this fault occurred on this phase only, replace the appropriate gate

driver board.

If this fault occurred on all three phases, check the 24V power supply

on the inverter power supply board that feeds the gate driver boards
and replace the inverter power supply board if necessary.

10135
10235
10335

I1 VBrd Fault
I2 VBrd Fault
I3 VBrd Fault

10136
10236
10336

I1 WBrd Fault
I2 WBrd Fault
I3 WBrd Fault

10137
10237
10337

I1 Cur Offset U
I2 Cur Offset U
I3 Cur Offset U

Alarm 1

The current sensor for the U, V, or W phase is not reading zero (off by
more than 1% of the inverter rated current), while the drive is not
running.

Check the current sensor’s offset reading inverter testpoint and

power supply. If necessary, replace the current sensor.

If this problem persists, replace the inverter power supply board and/

or the power layer interface board.

10138
10238
10338

I1 Cur Offset V
I2 Cur Offset V
I3 Cur Offset V

10139
10239
10339

I1 Cur Offset W
I2 Cur Offset W
I3 Cur Offset W

Event
No.

Fault/Alarm Text

Type

Fault
Action

Configuration
Parameter

Auto
Reset

Description/Action(s)