Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 138

Advertising
background image

138

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 3

Drive Port 0 Parameters

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

POSITION

C

O

NTR

O

L

Po

si

ti

on W

at

ch

745
748

PsnWatch1 Select
PsnWatch2 Select

Position Watch n Select
Selects a position feedback source that is compared to the position watch detect-input
P746 [PsnWatch1 DtctIn], P749 [PsnWatch2 DtctIn].

Default:
Min/Max:

847
1 / 159999

RW 32-bit

Integer

746
749

PsnWatch1 DtctIn
PsnWatch2 DtctIn

Position Watch n Detect Input
Provides position feedback source for the position watch function. The position watch
function is enabled and configured by the position control configuration P721 [Position
Control]. The position watch function compares this value to the position watch set
point P747 [PsnWatch1 Stpt], P750 [PsnWatch2 Stpt] when this parameter P746, P749
is selected by the position watch select P745 [PsnWatch1 Select], P748 [PsnWatch2
Select]. The position detect bit P724 [Psn Reg Status] Bit 9 “PsnW1Detect”, Bit 10
“PsnW2Detect” is set when the appropriate condition is satisfied.

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

747
750

PsnWatch1 Stpt
PsnWatch2 Stpt

Position Watch n Setpoint
Provides set point for the position watch function. The position watch function is
enabled and configured by P721 [Position Control]. The position watch function
compares this value to the position feedback source selected by the position watch
select P745 [PsnWatch1 Select], P748 [PsnWatch2 Select]. The position detect bit P724
[Psn Reg Status] Bit 9 “PsnW1Detect”, Bit 10 “PsnW2Detect” is set when the appropriate
condition is satisfied.

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

755

755

755

755

755

755

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta

T

yp

e

POSI

TI

ON C

O

N

TR

O

L

Inte

rpol

ator

755

Interp Control

Interpolator Control
Reserved for future use.

Default:
Options:

0
1 / 2147483647

RW 32-bit

Integer

756

Interp Psn Input

Interpolator Position Input
Input value to the Command Position fine interpolator.

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

757

Interp Vel Input

Interpolator Velocity Input
Input value to the Command Velocity fine interpolator.

Units:

Default:
Min/Max:

Hz
RPM
0.00
–/+1000000.00

RW Real

758

Interp Trq Input

Interpolator Torque Input
Input value to the Command Torque fine interpolator.

Default:
Min/Max:

0.00
–/+1000000.00

RW Real

759

Interp Psn Out

Interpolator Position Output
Output value from the Command Position fine interpolator.

Default:
Min/Max:

0
–2147483648 / 2147483647

RW 32-bit

Integer

760

Interp Vel Out

Interpolator Velocity Output
Output value from the Command Velocity fine interpolator. When no Command Velocity
signal is present when performing position control, this signal can be derived by scaling
the Differential Position output value of the Command Position fine interpolator.

Units:

Default:
Min/Max:

Hz
RPM
0.00
–/+1000000.00

RW Real

761

Interp Trq Out

Interpolator Torque Output
Command torque output from fine interpolator (if active) into torque input summing
junction when configured for toque control.

Default:
Min/Max:

0.00
–/+1000000.00

RW Real

755

755

755

755

755

755

755

Advertising