Port 10 and Port 11 Parameters

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

PR

ECHAR

G

E C

O

MM

ON

Met

erin

g

18

Main DC Bus Volt

Main DC Bus Voltage
Sets the main DC bus voltage.

Units:
Default:
Min/Max:

V DC
0.00
0.oo / 1200.00

RW Real

25

Gate Board Temp

Gate Board Temperature
The precharge system gate board temperature. This is the maximum gate board
temperature from all online precharge units.

Units:
Default:
Min/Max:

DegC
0.0
–/+200.0

RO

Real

755 (8+)

755 (8+)

Fil

e

Gro

u

p

No.

Display Name
Full Name
Description

Values

Read-W

ri

te

Da

ta

T

yp

e

PRECH

A

RGE C

O

MMON

Te

st

po

in

ts

30
32

Testpoint Sel 1
Testpoint Sel 2

Testpoint Selection 1, 2
Selects a source for [Testpoint Val n]. Used by the factory, typically for diagnostic
purposes.

Default:
Min/Max:

0
0 / 65535

RW 32-bit

Integer

31
33

Testpoint Val 1
Testpoint Val 2

Testpoint Value 1, 2
Displays data selected by [Testpoint Sel n].

Default:
Min/Max:

0.000000
–/+220000000.000000

RO

Real

755 (8+)
755 (8+)

755 (8+)
755 (8+)