Input signals torque reference inputs, Default settings – Yaskawa FSP Amplifier User Manual
Page 104

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-37
Input Signals
Torque Reference Inputs
The following input signals are used for torque control.
FSP Amplifier
Torque
reference
Speed
reference
CN1-9
CN1-10
CN1-5
CN1-6
represents twisted-pair
P
P
P
Torque reference
(analog voltage
Speed reference
(analog voltage
Ö
Input T-REF CN1-9
Torque Reference Input
Torque Control and
Programming
Ö
Input SG CN1-10
Signal Ground for the Torque
Reference Input
Torque Control and
Programming
These signals are used when torque control is selected.
Servomotor torque is controlled so that it is proportional to the input
voltage between T-REF and SG.
Reference torque (%)
-4
-8
-12
4
8
12
Input voltage (V)
The slope is set in Pn400.
Factory setting
100
200
300
-100
-200
-300
Default Settings
Parameter Pn400 establishes the voltage level that applies rated torque.
For example:
With Pn400 = 30
Vin (V)
Resulting Applied Torque
+3
100% of rated torque in forward direction
+9
300% of rated torque in forward direction
-0.3
10% of rated torque in reverse direction