Input signals torque reference inputs, Default settings – Yaskawa FSP Amplifier User Manual

Page 104

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-37

„

Input Signals

Torque Reference Inputs

The following input signals are used for torque control.

FSP Amplifier

Torque

reference

Speed

reference

CN1-9

CN1-10

CN1-5

CN1-6

represents twisted-pair

P

P

P

Torque reference

(analog voltage

Speed reference

(analog voltage

Ö

Input T-REF CN1-9

Torque Reference Input

Torque Control and
Programming

Ö

Input SG CN1-10

Signal Ground for the Torque
Reference Input

Torque Control and
Programming

These signals are used when torque control is selected.
Servomotor torque is controlled so that it is proportional to the input
voltage between T-REF and SG.

Reference torque (%)

-4

-8

-12

4

8

12

Input voltage (V)

The slope is set in Pn400.

Factory setting

100

200

300

-100

-200

-300

„

Default Settings

Parameter Pn400 establishes the voltage level that applies rated torque.
For example:

With Pn400 = 30

Vin (V)

Resulting Applied Torque

+3

100% of rated torque in forward direction

+9

300% of rated torque in forward direction

-0.3

10% of rated torque in reverse direction