FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-67

Parameter Signal

Setting

(rpm)

Control Mode

Pn503

Speed Coincidence Signal
Output Width

Range: 0 to 100
Default Setting: 10

Speed Control

This parameter is used to set conditions for speed coincidence signal
/TGON output.
The /V-CMP signal is output when the difference between the speed
reference and actual motor speed is below this setting.

Example:

The /V-CMP signal turns ON at 1900 to 2100 rpm if the parameter is set to 100 and the reference speed is

2000 rpm.

Note:

/V-CMP is a speed control signal. With the default setting, this signal is used as the positioning completed
signal /COIN for position control, and it is always ON for torque control.

5.5.5. Using the Running Output Signal (/TGON)

This section describes the basic use and wiring procedures for the running
(/TGON) output signal (photocoupler output signal). The signal can be
activated to indicate that the servomotor is currently operating. It is used as
an external interlock.

FSP Amplifier

Output Ö /TGON CN1-27

Running Output Signal

Speed, Torque, Position Control,
and Programming

/TGON State

Status

Result

ON

Closed or low level.

Servomotor is operating. (Motor speed is
above the setting level).

OFF

Open or high level.

Servomotor is not operating. (Motor speed is
below the setting level).

The following parameter setting is used to change the CN1 connector
terminal that outputs the /TGON signal.

Parameter Signal

Setting

Control Mode

Pn50E

Output Signal Selections 1

Default Setting: 3211

Speed, Torque,
Position Control,
and Programming