Follow the procedure below to manually adjust the speed reference offset.
1. Press the MODE/SET key to select the Auxiliary Function mode.

2. Press the Up Arrow or Down Arrow key to select the function Fn00A.

3. Press the DATA/SHIFT key for a minimum of one second, and the

display will be as shown below. The manual adjustment mode for the
speed reference offset will be entered.

4. Turn ON the Servo ON (/S-ON) signal. The display will be as shown

below.

5. Press the DATA/SHIFT key for less than one second to display the

speed reference offset value.

6. Press the Up Arrow or Down Arrow key to adjust the offset value

(adjustment of the speed reference offset).

7. Press the DATA/SHIFT key for less than one second to return to the

display shown in step 4 above.

8. Press the DATA/SHIFT key to return to the Auxiliary Function mode

display.

This completes the manual speed reference offset adjustment.