Pitch m, 32 4 d l j, Estimation of equivalent load ( j – Yaskawa FSP Amplifier User Manual
Page 180: 2n j j, Pitch

FSP Amplifier User’s Manual
Chapter 6: Servo Adjustment
6-13
The following wizard will help you to calculate your load inertia.
Estimation of equivalent load (
J
load
)
To tune your system, you should have an approximate estimation of the
Inertia (
J
load
) of the load attached to the motor.
If a cylinder load is mountain directly on motor axis you should
usefollowing formula to calculate load inertia:
32
4
d
l
J
load
×
×
×
=
ρ
π
Where ρ is the characteristic weight of the load [kg/m^3].
L is the length and d is the diameter of the load [m].
Estimation of Equivalent Load ( J
load
)
Case 1: Load is a cylinder directly mounted or coupled to motor axis:
32
4
d
l
J
load
×
×
×
=
ρ
π
ρ is the density of the load material [kg/m
3
]
L is the length
D is the diameter of the load [m]
Case 2: Load is driven through a gear with ratio N:
Equivalent load on motor is:
2
N
J
J
load
=
Case 3: Load is a mass driven by a ball screw having pitch:
2
Pitch
M
load
J
×
=
+ J
screw
+J
coupling
J
load
,
Æ Kg.m
2
, M
Æ Kg,
Pitch
Æ meter/radian
Other Cases: Make your own rough load inertia evaluations.