Yaskawa FSP Amplifier User Manual

Page 228

Advertising
background image

FSP Amplifier User’s Manual

Chapter 7: Using the Panel Operator

7-37

Follow the procedure below to set the write protection feature.
1.

Press the MODE/SET key to select the Auxiliary Function mode.

2.

Press the Up Arrow or Down Arrow key to select the function Fn010.

3.

Press the DATA/SHIFT key for a minimum of one second, and the

display will be as shown below.

4.

Input the value (0001) and press the MODE/SET key. The display will

change as shown below and the write protection will be established.

Flashing for
one second

5.

Press the DATA/SHIFT key for a minimum of one second to return to

the Auxiliary Function mode display.

This completes the procedure for setting the write protection. The new
password setting will be valid after the next power OFF/ON cycle.

Advertising