FSP Amplifier User’s Manual

Chapter 6: Servo Adjustment

6-5

6.2.4. Adjusting Offset

The servo system does not operate smoothly if reference voltage from the
host controller or external equipment has a reference offset value close to 0
V. In that case, adjust the reference offset value to 0 V.

„

Reference Voltage Offset from Host Controller or External
Circuitry

Offset

Reference

voltage

Reference

voltage

Reference speed

or torque

Make offset

adjustment with

The FSP Amplifier

Reference speed

or torque

Offset adjustment

„

Reference Offset Adjustment

The following two methods are provided to reset the reference offset value
to 0 V.
• Reference offset automatic adjustment

• Reference offset manual adjustment
If a position loop is formed in the host controller, be sure to make a manual
offset adjustment and no automatic reference offset adjustment.
Refer to the following sections in Chapter 7: Using the Panel Operator for
a detailed description of reference offset adjustment.

Adjustment Method

Detailed Description

Automatic

7.2.3 Automatic Adjustment of the Speed and
Torque Reference Offset

Manual

7.2.4 Manual Adjustment of the Speed and
Torque Reference Offset

Advertising