FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-46

5.3.2. JOG Speed

Use the following parameter to set or modify motor speed when operating
the servomotor from a panel or digital operator.

Parameter

Signal

Setting (rpm)

Control Mode

Pn304 JOG

Speed

Range: 0 to 10000
Default Setting: 500

Speed, Torque,
Position Control,
and Programming

If the setting is higher than the maximum motor speed of the servomotor,
then the servomotor will rotate at its maximum speed.

5.3.3. Input Circuit Signal Allocation

The functions allocated to sequence input signal circuits can be changed.
CN1 connector input signals are allocated with the default settings as
shown in the following table.

Default Setting

CN1 Connector

Terminal Numbers

Input Terminal

Name

Symbol Name

40 SI0 /S-ON

Servo

ON

41 SI1

/P-CON

(Proportional control
reference)*

42

SI2

P-OT

Forward run prohibit

43

SI3

N-OT

Reverse run prohibit

44 SI4

/ALM-RST

Alarm

reset

45

SI5

/P-CL

(Forward current limit)*

46

SI6

/N-CL

(Reverse current limit)*

Note: *

The functions of these input signals are automatically switched according to the setting for parameter

Pn000.1 as long as Pn50A.0 is set to 0.