5.3.2. JOG Speed
Use the following parameter to set or modify motor speed when operating
the servomotor from a panel or digital operator.
Parameter
Signal
Setting (rpm)
Control Mode
Pn304 JOG
Speed
Range: 0 to 10000
Default Setting: 500
Speed, Torque,
Position Control,
and Programming
If the setting is higher than the maximum motor speed of the servomotor,
then the servomotor will rotate at its maximum speed.
5.3.3. Input Circuit Signal Allocation
The functions allocated to sequence input signal circuits can be changed.
CN1 connector input signals are allocated with the default settings as
shown in the following table.
Default Setting
CN1 Connector
Terminal Numbers
Input Terminal
Name
Symbol Name
40 SI0 /S-ON
Servo
ON
41 SI1
/P-CON
(Proportional control
reference)*
42
SI2
P-OT
Forward run prohibit
43
SI3
N-OT
Reverse run prohibit
44 SI4
/ALM-RST
Alarm
reset
45
SI5
/P-CL
(Forward current limit)*
46
SI6
/N-CL
(Reverse current limit)*
Note: *
The functions of these input signals are automatically switched according to the setting for parameter