5.2.6. Contact Input Speed Control

This function provides a method for easy speed control. It allows the user
to initially set three different motor speeds with parameters, and then select
one of the speeds externally using a contact input.

Speed selection

SPEED 1 Pn301
SPEED 2 Pn302
SPEED 3 Pn303

M

Servomotor

Contact

input

/P- CON (/ SPD - D)

/P- CL (/ SPD - A)

/ N - CL (/ SPD - B)

CN1-41

CN1-45

CN1-46

External speed

setting devices and

pulse generation

are not required.

User constants

FSP Amplifier

Servomotor operates at

the speed set in the user

constant.

„

Using Contact Input Speed Control

Follow steps 1 to 3 below to use the contact input speed control function.
1. Set the following parameter to one of the speed control selections. The

default setting is "programming mode".

Parameter Signal Setting

Control

Mode

Pn000.1

Control Mode
Selection

Default Setting: D

Speed, Torque,
Position Control,
and Programming


The speed can be controlled via contact inputs.