C.3. surge suppressor, C.4. magnetic contactor, C.5. variable resistor for speed setting – Yaskawa FSP Amplifier User Manual

Page 337: C.6. cn1 i/o signal connector, Connection to an external power supply

Advertising
background image

FSP Amplifier User’s Manual

Appendix C: Specifications for Peripheral Devices

C-6

C.3. Surge Suppressor

Recommended to install surge suppressor that absorbs surge voltage generated
when the magnetic coil is OFF. This prevents faulty operation or damage to
electronic circuits near the magnetic contactors or switches.

C.4. Magnetic Contactor

A magnetic contactor turns ON and OFF the servo. Be sure to attach a surge
suppressor to the excitation coil of the magnetic contactor.
Select a magnetic contactor based on the current capacity of the FSP amplifier.
For multiply servo systems, select a contactor based on total current capacity.

C.5. Variable Resistor for Speed Setting

A variable resistor provides speed references by applying speed reference voltage
from the external power supply across CN1 pins 1 and 5 as well as 1 and 6.

„

Connection to an External Power Supply

P

V-REF

2 k

Ω

470 Ω , 1/2W min.

+ 12V

SG

CN1-5

CN1-6

FSP Amplifier

C.6. CN1 I/O Signal Connector

CN1 connector is required to connect the host controller to FSP Amplifier. It is
comprised of a connector and a case.

Connector Parts

YEA P/N of Connector

Connector

Model

Case

Model

JZSP-CKI9

10150-3000VE *

10350-52A0-008 *

* Manufactured by Sumitomo 3M Co.