Output Signal Monitor Display
7 6 5 4 3 2 1
Top: OFF ("H" level)
Bottom: ON ("L" level)
Number
LED Number
Output Terminal Name
Default Setting
1 (CN1-31,
-32)
ALM
2
SO1 (CN1-25, -26)
/COIN or /V-CMP
3
SO2 (CN1-27, -28)
/TGON
4
SO3 (CN1-29, -30)
/S-RDY
5 (CN1-37)
AL01
6 (CN1-38)
AL02
7 (CN1-39)
AL03
Note: Refer to 5.3.4 Output Circuit Signal Allocation for details on output terminals.
Output signals are allocated as shown above and displayed on the panel of
the servo amplifier or the digital operator. They are indicated by the
ON/OFF status of the vertical parts of seven-segment displays located in
top and bottom rows. (The horizontal segments are not used here). These
vertical segments turn ON or OFF relative to the state of the corresponding
output signals (ON for “L” level and OFF for “H” level).
Example
• When ALM signal operates (alarm at “H”)
7 6 5 4 3 2 1
The top segment of
number 1 is lit.