Important – Yaskawa FSP Amplifier User Manual
Page 226

FSP Amplifier User’s Manual
Chapter 7: Using the Panel Operator
7-35
4.
Press the MODE/SET key. The display will change as shown below,
and the offset will be automatically adjusted.
Flashing for
one second
5.
Press the DATA/SHIFT key for a minimum of one second to return to
the Auxiliary Function mode display.
This completes the automatic adjustment of the motor current detection
offset.
Manually Adjusting the Motor Current Detection Offset
Follow the procedure below to manually adjust the current detection offset.
IMPORTANT
• When making manual adjustments, run the motor at a speed of
approximately 100rpm, and adjust the Motor Current Detection Offset
until the torque ripple, observed with the analog monitor, is minimized.
(Refer to Section 6.4. Analog Monitor.)
Adjust the U-phase and V-phase offsets alternately several times until these
offsets are well balanced.
1.
Press the MODE/SET key to select the Auxiliary Function mode.
2.
Press the Up Arrow or Down Arrow key to select the function Fn00F.
3.
Press the DATA/SHIFT key for a minimum of one second, and the
display will be as shown below.