FSP Amplifier User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9-41

9.2.4. Warning Displays

The correlation between warning displays and warning code outputs is
shown in the following table.

Warning Code Outputs

Warning

Display

ALO1

ALO2

ALO3

Warning

Name

Meaning of Warning

A.91 ON

OFF

OFF

Overload

This warning occurs before either of
the overload alarms (A.71 or A.72)
occurs. If the warning is ignored and
operation continues, an overload
alarm may result.

A.92 OFF

ON

OFF

Regenerative
Overload

This warning occurs before the
regenerative overload alarm (A.32)
occurs. If the warning is ignored and
operation continues, a regenerative
overload alarm may result.