Status display mode, Selecting status display mode, Data in status display mode – Yaskawa FSP Amplifier User Manual

Page 195: Speed and torque control mode

Advertising
background image

FSP Amplifier User’s Manual

Chapter 7: Using the Panel Operator

7-4

7.1.4. Status Display Mode

In Status Display mode, bit data and codes are displayed to indicate the
status of the servo amplifier.

„

Selecting Status Display Mode

The digital operator goes into Status Display mode when the digital
operator is turned ON.

„

Data in Status Display Mode

Screen contents in Status Display mode are different for Speed, Torque,
Position Control, and Programming modes.

Speed and Torque Control Mode

Bit Data

Code

Speed Coincidence*

Baseblock

Control Power ON

Speed Reference Input

TGON

Power Ready

Torque Reference Input

* This indicator is always lit when the FSP Amplifier is in Torque Control mode

The following tables list and explain the meanings of bit data and code
displays in Speed and Torque Control modes.

Bit Data and Meanings in Speed and Torque Control Mode

Bit Data

Meaning

Control Power ON

Lit when servo amplifier control power is ON.

Baseblock

Lit for baseblock.
Not lit when servo is ON.

Speed Coincidence

Lit when the difference between motor speed and reference speed is
the same as or less than the value set in Pn503.
(Default setting: 10 rpm).

/TGON

Lit if motor speed exceeds preset value
Preset value: Set in Pn502. (Default setting: 20 rpm).

Speed Reference Input

Lit if input speed reference exceeds preset value.
Specified value: Set in Pn502. (Default setting: 20 rpm)

Torque Reference Input

Lit if input torque reference exceeds preset value.
Preset value: 10% of rated torque is the default setting

Power Ready

Lit when main power supply circuit is operating at normal level.
Not lit when power is OFF.

Advertising