Fsp amplifier inspection and maintenance, Servomotor inspection, Important – Yaskawa FSP Amplifier User Manual

Page 267

Advertising
background image

FSP Amplifier User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9-2

9.1. FSP Amplifier Inspection and Maintenance

This section describes the basic inspections and maintenance of servomotors and
servo amplifiers and the procedures for replacing the battery for absolute
encoders.

9.1.1. Servomotor Inspection

For inspection and maintenance of servomotors, follow the simple, daily
inspection procedures in the following table.
The AC servomotors are brushless. Simple, daily inspection is sufficient
under most conditions. The inspection and maintenance frequencies in the
table are only guidelines. Increase or decrease the frequency to suit the
operating conditions and environment.

IMPORTANT

During inspection and maintenance, do not disassemble the servomotor.

If disassembly of the servomotor is required, contact Yaskawa.

Servomotor Inspection

Action or Problem

Frequency Procedure Comments

Vibration and Noise

Daily

Touch and listen.

Levels higher than
normal?

Exterior Dirt

According to degree of
contamination

Clean with cloth or
compressed air.

Insulation
Resistance
Measurement

At least every year

Disconnect servo amplifier
and test insulation
resistance at 500 V. Must
exceed 10 MΩ*

Contact Yaskawa if the
insulation resistance is
below 10 MΩ

Oil Seal
Replacement

At least every 5000
hours

Remove servomotor from
machine and replace oil
seal.

Applies only to motors with
oil seals.

Servomotor
Overhaul

At least every 20000
hours or 5 years

Contact YEA

The user should not
disassemble and clean the
servomotor.

* Measure across the servomotor FG and the U-phase, V-phase, or W-phase power line

Advertising