Yaskawa FSP Amplifier User Manual

Page 238

Advertising
background image

FSP Amplifier User’s Manual

Chapter 8: Ratings, Specifications and Dimensional Drawings

8-9

8.5. Three-phase 400 V FSP Amplifier and Motors Combinations

FSP Amplifier Model FSP-

05D*

10D*

15D*

20D*

30D*

50D*

Model SGMGH-

05D

09D

13D 20D

30D

44D

Capacity

(kW)

0.45 0.85 1.30 1.80 2.90 4.40

Appli

cab

le

Serv

om

otor

Motor Speed (rpm)

Rated 1500, maximum 3000

Applicable Encoder

YASKAWA serial or incremental A quad B or absolute encoder.

DIFFERENT incremental A quad B encoders

Continuous Output Current

A

rms

1.9 3.5 5.4 8.4 11.9 16.5

Maximum Output Current A

rms

5.5 8.5 14 20 28 40.5

SGM

G

H Series

(Yask

aw

a or

co

mpat

ibl

e)

Allowable Regenerative
Frequency* (times / min)

42 15 10 12 8 11

Model SGMSH-

10D

15D 30D

30D

40D 50D

Capacity (KW)

1.00

1.50 3.00 3.00

4.00

5.00

Appli

cab

le

Serv

om

otor

Motor Speed (rpm)

Rated 3000, maximum 5000

Applicable Encoder

YASKAWA serial or incremental A quad B or absolute encoder.

DIFFERENT incremental A quad B encoders

Continuous Output Current

A

rms

— 2.8 4.7 6.2 8.9

12.5

13.8

Maximum Output Current A

rms

— 8.5 14 19.5

28

38

42

SGM

SH Serie

s

(Yask

aw

a or

co

mpat

ibl

e)

Allowable Regenerative
Frequency* (times / min)

— 47 31 48 20

29

22

Model SGMUH-

10D

15D

30D

Capacity (KW)

1.00

1.50

3.00

Appli

cab

le

Servo

m

otor

Motor Speed (rpm)

Rated 6000, maximum 6000

Applicable Encoder

YASKAWA serial or incremental A quad B or absolute encoder.

DIFFERENT incremental A quad B encoders

Continuous Output Current A

rms

— 2.7 4.1 — 8.1

Maximum Output Current A

rms

— 8.5 14 — 28

SGM

UH Series

(Yask

aw

a or

co

mpat

ibl

e)

Allowable Regenerative
Frequency* (times / min)

— 27 19 — 13


*
Allowable regenerative frequency is the allowable frequency in the motor while accelerating and decelerating
through a 0 Æ maximum motor speed

Æ 0 (r / min) cycle.

Note: Refer to Chapter 5.6 Selecting a Regenerative Resistor for more details on allowable regenerative energy

and frequency.

Advertising