Nct gain parameters – Yaskawa FSP Amplifier User Manual

Page 182

Advertising
background image

FSP Amplifier User’s Manual

Chapter 6: Servo Adjustment

6-15

6.3.3. NCT Gain Parameters

The following are the main parameters of NCT servo control:
Kd Pn1AC

Differential

gain

Kp Pn1AA Proportional

gain

Kiv Pn1AB

Additional proportional gain

Kis Pn1A9

Integral

feedback

gain


These parameters should be tuned in the order of the list above.

Kd (Pn1AC) range 0 to 2000 [Hz] default 80:

This parameter is equivalent to a velocity loop gain. It produces
damping of the movement.
The higher this parameter can be increased, the better the final tuning
will be. However, the increase is limited by the flexibility of the
mechanical system driven.
A too high value of Kd will cause high frequency oscillations of the
system.
For tuning, raise the value of that parameter progressively until
oscillations are observed or acoustic noise is heard. Then reduce back to
a safe value (around 10 to 20%, depending on the system).

Kp (Pn1AA) range 0 to 500 [Hz] default 40:

This parameter sets the position loop gain.
For tight control, increase it until overshoot or oscillations are observed.
Then reduce back and set according to the level of
overshoot/undershoot desired.
Value 30 * (J

total

/ J

motor

)

0.5

can be used as a reference value.

Kiv (Pn1AB) range 0 to 500 [Hz], default 30:

This parameter is an additional position loop gain. Using proprietary
NCT technique, this gain increases stiffness and reduces the position
error during the trajectory following, without causing overshoot or
oscillations.
Proceed as for Kp for tuning. Normally, the range of this parameter is

Kp / 2 < Kiv < Kp