FSP Amplifier User’s Manual
Chapter 3: Wiring
3-23
• Connecting an optocoupler output circuit
An optocoupler output circuits are used for servo alarm, servo ready,
and other sequence output signal circuits.
Connect an optocoupler output circuit through a relay or line receiver
circuit.
FSP Amplifier
FSP Amplifier
Note:
The maximum allowable capacities for optocoupler output circuits are:
• Voltage: 30 VDC
• Current: 50 mA
DC
• Connecting two FSP Amplifiers (master-slave mode):
Connect output of “master” FSP Amplifier to input of “slave” FSP
Amplifier.
FSP Master
FSP Slave
• Connecting an external load to FSP Amplifier’s output.
Maximum current: 50 mA.
FSP Amplifier