• Connecting an optocoupler output circuit

An optocoupler output circuits are used for servo alarm, servo ready,
and other sequence output signal circuits.
Connect an optocoupler output circuit through a relay or line receiver
circuit.

FSP Amplifier

FSP Amplifier

Note:

The maximum allowable capacities for optocoupler output circuits are:

• Voltage: 30 VDC
• Current: 50 mA

DC

• Connecting two FSP Amplifiers (master-slave mode):

Connect output of “master” FSP Amplifier to input of “slave” FSP
Amplifier.

FSP Master

FSP Slave

• Connecting an external load to FSP Amplifier’s output.

Maximum current: 50 mA.