FSP Amplifier User’s Manual

Appendix D: List of Parameters

D-14

D.5. Auxiliary Functions

The following list shows the available auxiliary functions.

Parameter Function

Fn000

Alarm trace-back data display

Fn001

Rigidity setting during online auto-tuning

Fn002

JOG mode operation

Fn003

Zero-point search mode

Fn004

(Reserved function; do not change)

Fn005

Parameter settings initialization

Fn006

Alarm trace-back data clear

Fn007

Writing to EEPROM the inertia ratio data obtained from online auto-tuning

Fn008

Absolute encoder multi-turn reset and encoder alarm reset.

Fn009

Automatic tuning of analog (speed, torque) reference offset

Fn00A

Manual adjustment of speed reference offset

Fn00B

Manual adjustment of torque reference offset

Fn00C

Manual zero-adjustment of analog monitor output

Fn00D

Manual gain-adjustment of analog monitor output

Fn00E

Automatic offset-adjustment of motor current detection signal

Fn00F

Manual offset-adjustment of motor current detection signal

Fn010

Password setting (protects from parameter & some function changes)

Fn011

Motor models display

Fn012

Software version display

Fn013

Set absolute encoder multi-turn limit

D.6. Monitor Modes

The following list shows monitor modes available

Parameter

Content of Display

Unit

Remarks

Un000

Motor speed

rpm

Measured motor speed.

Un001

Input speed reference

rpm

Commanded motor speed.

Un002

Internal torque reference

% of rated

torque

Present torque applied to motor.

Un003 Rotation

angle

1

pulses

Number of pulses from the origin
(Used for commutation; not generally
useful to user).

Un004 Rotation

angle

2

degrees

Electrical angle from the origin
(Used for commutation; not generally
useful to user).

Un005

Input signal monitor

On/Off status of inputs.

Un006

Output signal monitor

On/Off status of outputs.

Un007

Input reference pulse speed

rpm

Un008*

Error counter value

reference unit

Error between commanded position and
actual motor position.

Un009

Accumulated load rate

% of rated

torque

RMS torque over the last 10 seconds.

Un00A

Regenerative load rate

% of max.

regenerative

power

Average power dissipated by the
regenerative resistor over the last 10
seconds.

Un00B

Power consumed by DB
resistor

% of max

Average power consumed by the dynamic
braking resistor over the last 10 seconds.
This is equivalent to the value for the
processable power when dynamic brake is
applied at 100%.

Un00C

Input reference pulse
counter

Number of

pulses (in hex)

Number of command pulses received by
the amplifier.

Un00D

Feedback pulse counter

Number of

pulses (in hex)

Number of feedback pulses received by
the amplifier. (See notes 2 and 4 below)

*Not used in serial communication command.