Chapter 5: Parameter Settings and Functions

5-51

„

Allocating Other Output Signals

Parameter

Output Signal

Number

Setting

Description

0

Disabled. (Not used for the specified output
signal.)

1

Outputs the specified signal from the SO1
(CN1-25 and 26) output terminal.

2

Outputs the specified signal from the SO2
(CN1-27 and 28) output terminal.

Positioning Completed
(/COIN)

Pn50E.0

3

Outputs the specified signal from the SO3
(CN1-29 and 30) output terminal.

Speed Coincidence
Detection (/V -CMP)

Pn50E.1

0 to 3

Rotation Detection
(/TGON)

Pn50E.2

0 to 3

Servo Ready
(/S-RDY)

Pn50E.3

0 to 3

Torque Limit Detection
(/CLT)

Pn50F.0

0 to 3

Speed Limit Detection
(/VLT)

Pn50F.1

0 to 3

Brake Interlock
(/BK)

Pn50F.2

0 to 3

Warning (/WARN)

Pn50F.3

0 to 3

Near (/NEAR)

Pn510.0

0 to 3

Same as above.
(Output signals are disabled or allocated to
output terminals SO1 to SO3 through
parameter settings 0 to 3).

Not used

Note:

Signals are output with OR logic when multiple signals are allocated to the same output circuit.
Signals that are not detected are invalid. For example, the positioning completed signal /COIN is invalid in
Speed Control mode.