Limiting torque, Setting level 1: internal torque limits – Yaskawa FSP Amplifier User Manual

Page 75

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-8

5.1.3. Limiting Torque

The FSP Amplifier limits torque as follows:
• Level 1: Limits maximum output torque to protect equipment or work

piece.

• Level 2: Limits torque after the servomotor moves the equipment to a

specified position (external torque limit).

• Level 3: Always limits output torque rather than speed.

• Level 4: Switches between speed and torque limit.
The application of level 1 and 2 in the torque limit function is described
below.

„

Setting Level 1: Internal Torque Limits

Maximum torque is limited to the values set in the following parameters.

Parameter Signal

Setting

(% of Rated Torque)

Control Mode

Pn402

Forward Torque Limit

Range: 0 to 800
Default Setting: 800

Speed, Torque,
Position Control, and
Programming

Pn403

Reverse Torque Limit

Range: 0 to 800
Default Setting: 800

Speed, Torque,
Position Control, and
Programming

Sets the maximum torque limits for forward and reverse rotation.
Used when torque must be limited due to equipment conditions.
The torque limit function always monitors torque and outputs the signals
below when the limit is reached.

Signal Description

/CLT

Generated when Pn50F.0 allocates an output terminal from SO1 to
SO3.

Monitor Mode (Un006)

Output signal monitor

Torque limits are specified as a percentage of the rated torque.

Note: If the torque limit is set higher than the maximum torque of the servomotor, the maximum torque of the

servomotor is the limit.

Application Example: Equipment Protection

Torque limit

Motor
speed

Torque

Too small a torque limit will result in an
insufficient torque during acceleration and
deceleration

Advertising