Servo amplifier power losses – Yaskawa FSP Amplifier User Manual

Page 39

Advertising
background image

FSP Amplifier User’s Manual

Chapter 3: Wiring

3-14

3.3.3. Servo Amplifier Power Losses

The following table shows servo amplifier power losses at the rated output.

Table 3.2: Servo Amplifier Power Losses at Rated Output

Main

Circuit
Power

Supply

Maximum

Applicable

Servomotor

Capacity

[kW]

Servo Amplifier

Model

Output

Current

(Effective

Value) [A]

Main

Circuit
Power

Loss

[W]

Regenerative

Resistor

Power Loss

[W]

Control

Circuit
Power

Loss

[W]

Total

Power

Loss

[W]

0.03 FSP-A3B*

0.66

3.5

16.5

0.05 FSP-A5B*

0.95

5.2

18.2

0.10 FSP-01B* 2.4 12

25

Single-

phase

100 V

0.20 FSP-02B* 3.0

16.4

— 13

29.4

0.03 FSP-A3A*

0.44

3.1

16.1

0.05 FSP-A5A*

0.64

4.6

17.6

0.10 FSP-01A*

0.91

6.7

19.7

0.20 FSP-02A* 2.1

13.3

26.3

Single-

phase

200 V

0.40 FSP-04A* 2.8 20

— 13

33

0.75 FSP-08A* 4.4 47 12

74

Single-

phase

220 V

1.50 FSP-15A* 7.5 60 14

15

89

1.00 FSP-10A* 7.6 55 12

82

2.00 FSP-20A*

18.5

120

163

Three-

phase

200 V

3.00 FSP-30A* 7.5 60

28

15

198

0.50 FSP-05D* 1.9 19

48

1.00 FSP-10D* 3.5 35

64

1.50 FSP-15D* 5.4 53

14

82

2.00 FSP-20D* 8.4 83

126

3.00 FSP-30D*

11.9

118

28

15

161

Three-

phase

400 V

5

.00 FSP-

5

0D* 16.5 192 36

15 243

Note: Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded:

•

Disconnect the internal regenerative resistor in the servo amplifier by removing the wire

between terminals B2 and B3.

•

Install an external regenerative resistor between terminals B1 and B2.

See 5.6 Selecting a Regenerative Resistor for more details on the resistors.


Advertising