Servo amplifier power losses – Yaskawa FSP Amplifier User Manual

Page 39

Advertising
background image

FSP Amplifier User’s Manual

Chapter 3: Wiring

3-14

3.3.3. Servo Amplifier Power Losses

The following table shows servo amplifier power losses at the rated output.

Table 3.2: Servo Amplifier Power Losses at Rated Output

Main

Circuit
Power

Supply

Maximum

Applicable

Servomotor

Capacity

[kW]

Servo Amplifier

Model

Output

Current

(Effective

Value) [A]

Main

Circuit
Power

Loss

[W]

Regenerative

Resistor

Power Loss

[W]

Control

Circuit
Power

Loss

[W]

Total

Power

Loss

[W]

0.03 FSP-A3B*

0.66

3.5

16.5

0.05 FSP-A5B*

0.95

5.2

18.2

0.10 FSP-01B* 2.4 12

25

Single-

phase

100 V

0.20 FSP-02B* 3.0

16.4

— 13

29.4

0.03 FSP-A3A*

0.44

3.1

16.1

0.05 FSP-A5A*

0.64

4.6

17.6

0.10 FSP-01A*

0.91

6.7

19.7

0.20 FSP-02A* 2.1

13.3

26.3

Single-

phase

200 V

0.40 FSP-04A* 2.8 20

— 13

33

0.75 FSP-08A* 4.4 47 12

74

Single-

phase

220 V

1.50 FSP-15A* 7.5 60 14

15

89

1.00 FSP-10A* 7.6 55 12

82

2.00 FSP-20A*

18.5

120

163

Three-

phase

200 V

3.00 FSP-30A* 7.5 60

28

15

198

0.50 FSP-05D* 1.9 19

48

1.00 FSP-10D* 3.5 35

64

1.50 FSP-15D* 5.4 53

14

82

2.00 FSP-20D* 8.4 83

126

3.00 FSP-30D*

11.9

118

28

15

161

Three-

phase

400 V

5

.00 FSP-

5

0D* 16.5 192 36

15 243

Note: Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded:

Disconnect the internal regenerative resistor in the servo amplifier by removing the wire

between terminals B2 and B3.

Install an external regenerative resistor between terminals B1 and B2.

See 5.6 Selecting a Regenerative Resistor for more details on the resistors.


Advertising