FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-66

(per output)

0V

Photocoupler output

Maximum operating

voltage: 30 VDC

50mA DC

Maximum output current:

I/ O power supply

XtraDrive

FSP Amplifier

Output Ö /V-CMP CN1-25

Speed Coincidence Output
Signal

Speed Control


This signal is output when the actual motor speed during speed control is
the same as the speed reference input.

/V-CMP State

Status

Result

ON

Circuit between CN1-25 and 26 is
closed, and CN1-25 is at low level.

Speed coincides. (Speed error is below the
setting.)

OFF

Circuit between CN1-25 and 26 is
open, and CN1-25 is at high level.

Speed does not coincide. (Speed error is
above the setting.)

The following parameter setting is used to change the CN1 connector
terminal that outputs the /V-CMP signal.

Parameter Signal

Setting

Control Mode

Pn50E

Output Signal Selections 1

Default Setting: 3211

Speed, Torque,
Position Control,
and Programming

The parameter is default set so the /V-CMP signal is output between CN1-
25 and 26. See 5.3.4 Output Circuit Signal Allocation for more details on
parameter Pn50E.
The following parameter is used to set conditions for speed coincidence
output.