Chapter 7: Using the Panel Operator

7-36

4.

Press the MODE/SET key to switch between U-phase (Cu1_0) and V-

phase (Cu2_0) current detection offset adjustment mode.

MODE/SET key

Displays
alternately

5.

Press the DATA/SHIFT key for less than one second to display the

current detection data. Press the DATA/SHIFT key again for less than
one second, and the display will return to show as in step 3 or 4 above.

DATA/SHIFT key

Displays

alternately

Data display

6.

Press the Up Arrow or Down Arrow key to adjust the offset. Carefully

adjust the offset while monitoring the torque reference monitor signal.

Data setting change

7.

When the current offset adjustment has been completed for the U-phase

(Cu1_0) and V-phase (Cu2_0), press the DATA/SHIFT key to return
to the Auxiliary Function mode display.

This completes the manual adjustment of the motor current detection
offset.

7.2.12. Write Protection Setting

The write protection setting is used to prevent careless changes of
parameters. All Pn parameters and some of the Fn functions become write
protected by setting the function Fn010.
Password setting values are as follows:
• “0000”: Write enabled (releases write protected mode.)

• “0001”: Write prohibited (parameters become write protected at the

next power ON.)