FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-45

„

Relationship between Inhibit Signal and Reference Pulses

t1

t2

ON

OFF

ON

t1, t2 > 0.5 ms

=

Input reference pulses

are not counted

during this period.

/INHIBIT signal

(/P-CON)

Reference

pulse

5.3. Setting Up the Servo Amplifier

This section describes the procedure of setting parameters to operate the
FSP servo amplifier.

5.3.1. Parameters

The FSP Series Servo Amplifier provides many functions and has
parameters that allow the user to specify functions and perform fine
adjustments.
Parameters are divided into the following three groups.

Parameter Function

Pn000 to Pn601

Specify servo amplifier functions, set
servo gains, etc.

Fn000 to Fn012

Execute auxiliary functions such as JOG
mode operations and origin searches.

Un000 to Un00D

Enable monitoring the motor speed and
torque reference on the panel display.

Note:

Appendix B shows a list of parameters provided for reference. See

7.1.5 Operation in Parameter Setting

Mode for more details on the parameter setting procedure.