Yaskawa FSP Amplifier User Manual
Page 210

FSP Amplifier User’s Manual
Chapter 7: Using the Panel Operator
7-19
3. Press the MODE/SET key to set the servo to ON (with motor power
turned ON).
4. Press the Up Arrow or Down Arrow key to operate the motor. The
motor keeps operating while the key is pressed.
5. Press the MODE/SET key to set the servo to OFF state (with motor
power turned OFF). Alternatively, press the DATA/SHIFT key for a
minimum of one second to set the servo to OFF state.
6. Press the DATA/SHIFT key for a minimum of one second, and the
display will revert to Fn002 in the Auxiliary Function mode.
This ends JOG operation under panel operator control.
The motor speed for operation under digital operator control can be
changed with the following parameter:
Parameter
Signal
Setting (rpm)
Control Mode
Pn304
Jog Speed
Default Setting: 500
Speed Control
Note: The rotation direction of the servomotor depends on the setting of parameter Pn000.0 “Rotation Direction.”
The above example shows a case where Pn000.0 is set to “0” as a default setting.