Input pulse multiplier – Yaskawa FSP Amplifier User Manual

Page 84

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-17

Par

am

et

e

r

Pn

20

0.0

Reference

Pulse Form

Input

Pu

lse

Multiplier

Logic

Forward Rotation

Reference

Reverse Rotation

Reference

0

Sign + pulse

train

---

High

PULS
(CN1-7)

SIGN
(CN1-11)

Low

PULS
(CN1-7)

SIGN
(CN1-11)

1

CW pulse +

CCW pulse

---

Low

PULS
(CN1-7)

SIGN
(CN1-11)

Low

PULS
(CN1-7)

SIGN
(CN1-11)

2 x1

3 x2

4

Two-phase

pulse train

with 90°

phase

differential

x4

P

o

sit

ive

PULS
(CN1-7)

SIGN
(CN1-11)

90°

PULS
(CN1-7)

SIGN
(CN1-11)

90°

5

Sign + pulse

train

---

Low

PULS
(CN1-7)

SIGN
(CN1-11)

High

PULS
(CN1-7)

SIGN
(CN1-11)

6

CW pulse +

CCW pulse

---

High

PULS
(CN1-7)

SIGN
(CN1-11)

High

PULS
(CN1-7)

SIGN
(CN1-11)

7 x1

8 x2

9

Two-phase

pulse train

with 90°

phase

differential

x4

N

egati

ve

PULS
(CN1-7)

SIGN
(CN1-11)

90°

PULS
(CN1-7)

SIGN
(CN1-11)

90°

Input Pulse Multiplier

The input pulse multiplier function can be used if the reference pulse is a
two-phase pulse train with a 90

° phase differential. The electronic gear

function can also be used to convert input pulses.

Advertising