Servo amplifier orientation, Cooling, Side-by-side installation – Yaskawa FSP Amplifier User Manual

Page 25: Environmental conditions in the control panel

Advertising
background image

FSP Amplifier User’s Manual

Chapter 2: Installation

2-4

„

Servo Amplifier Orientation

Install the servo amplifier perpendicular to the wall so the front panels’
connectors face outward.

„

Cooling

As shown in the figure, allow sufficient space around each servo amplifier
for cooling by cooling fans or natural convection.

„

Side-by-side Installation

When installing servo amplifiers side-by-side as shown in the figure, allow
at least 0.39 in (10 mm) between and at least 1.97 in (50 mm) above and
below each servo amplifier. Install cooling fans above the servo amplifiers
to avoid excessive temperature rise and to maintain even temperature inside
the control panel.

„

Environmental Conditions in the Control
Panel

• Ambient

Temperature:

0

to

55°C

• Humidity:

90%

RH

or

less

• Vibration:

0.5

G

(4.9

m/s

2

)

• Condensation and Freezing:

None

• Ambient Temperature for Long-term Reliability: 45°C max.

Advertising