FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-64

Set the following parameter to 7 if the /S-ON signal will not be used.

Parameter Signal Setting Control

Mode

Pn50A.1

/S-ON Signal Mapping

Default Setting: 0

Speed, Torque, and Position
Control

CN1

-40

(/S-ON)

The external short-circuit wiring shown
in the figure can be omitted if the Servo
ON (/S-ON) input signal is not used.

FSP Amplifier

0V

Pn50A.1

Setting

Status Result

0

Enables the servo ON
(/S-ON) input signal.

The servo is OFF when CN-40 is open and ON when
CN1-40 is at 0 V.

7

Disables the servo ON
(/S-ON) input signal.

The servo is always ON and has the same effect as
shorting CN1-40 to 0 V.

Note:

See

5.3.3 Input Circuit Signal Allocation for other Pn50A.1 settings.

5.5.3. Using the Positioning Completed Output Signal (/COIN)

This section describes the basic use and wiring procedures for the
positioning completed (/COIN) output signal (photocoupler output signal).
The signal is output to indicate that servomotor operation is completed.

(per output)

0V

Photocoupler output

Maximum operating

voltage: 30 VDC

50mA DC

Maximum output current:

XtraDrive

/ COIN+

/ COIN-

FSP Amplifier

Output Ö /COIN CN1-25

Positioning Completed Output
Signal

Position Control

This signal indicates that the servomotor movement during position control
has been completed. The host controller uses the signal as an interlock to
confirm that positioning is completed.

Reference speed

Speed

Motor speed

Time

Error pulse
(Un008)

/COIN
(CN1-25)

Pn500