FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-50

5.3.4. Output Circuit Signal Allocation

„

Output Signal Allocation

Output signal functions can be allocated to the sequence signal output
circuits shown below.

Default Setting

CN1 Connector

Terminal

Numbers

Output

Terminal

Name

Symbol Name

Comments

25

/V-CMP+
(/COIN+)

26 (SG)

SO1

/V-CMP–
(/COIN–)

Speed coincidence
detection
(positioning
completed)

The signal output
will vary depending
on the control mode.

27 /TGON+

28 (SG)

SO2

/TGON–

Rotation detection

29 /S-RDY+

30 (SG)

SO3

/S-RDY–

Servo ready

„

Output Signal Selection Default Settings

The output signal selection parameters and their default settings are shown
below.

Parameter Signal

Setting

Control

Mode

Pn50E

Output Signal Selections 1

Default Setting: 3211

Speed, Torque, Position
Control, and
Programming

Pn50F

Output Signal Selections 2

Default Setting: 0000

Speed, Torque, Position
Control, and
Programming

Pn510

Output Signal Selections 3

Default Setting: 0000

Speed, Torque, Position
Control, and
Programming

Select the CN1 connector terminals that will output the signals.

Output

signal

SO1 (CN1-25, 26)

SO2 (CN1-27, 28)

SO3 (CN1-29, 30)

Pn50E. to Pn510.