Alarm Code Output

Alarm

Display ALO1 ALO2 ALO3

ALM

Output

Alarm Name

Description

A.81*

Absolute Encoder
Backup Error*

All the power supplies for the
absolute encoder have failed
and position data was cleared.

A.82*

Encoder Checksum
Error*

The checksum results of
encoder memory is abnormal.

A.83

Absolute Encoder
Battery Error

Battery voltage for the absolute
encoder has dropped.

A.84*

Absolute Encoder Data
Error*

Received absolute data is
abnormal.

A.85

Absolute Encoder
Overspeed

The encoder was rotating at
high speed when the power was
turned ON.

A.86 Encoder

Overheated

The internal temperature of
encoder is too high.

A.b1

Reference Speed Input
Read Error

The A/D converter for reference
speed input is faulty.

A.b2

Reference Torque
Input Read Error

The A/D converter for reference
torque input is faulty.

A.bF*

OFF OFF OFF OFF

System Alarm*

A system error occurred in the
servo amplifier.

A.C1

Servo Overrun
Detected

The servomotor ran out of
control.

A.C2 Phase

Finding

Error

The commutation (phase
finding) procedure for motor
with A quad B encoder was
faulty.

A.C8*

Absolute Encoder
Clear Error and Multi-
Turn Limit Setting
Error*

The multi-turn for the absolute
encoder was not properly
cleared or set.

A.C9*

ON OFF ON OFF

Encoder
Communications Error*

Communications between servo
amplifier and encoder is not
possible.

A.CA*

Encoder Parameter
Error*

Encoder parameters are faulty.

A.Cb*

Encoder Echo back
Error*

Contents of communications
with encoder is incorrect.

A.CC

ON OFF ON OFF

Multi-Turn Limit
Disagreement

Different multi-turn limits have
been set in the encoder and
servo amplifier.

A.d0 ON ON OFF OFF

Position Error Pulse
Overflow

Position error pulse exceeded
parameter (Pn505).

A.F1 OFF ON OFF OFF

Power Line Open
Phase

One phase is not connected in
the main power supply

A.--

OFF

OFF

OFF

ON

Not an error

Normal operation status

*

These alarms are not reset by the alarm reset signal (/ALM-RST). Eliminate the cause of the alarm and
then turn OFF the power supply to reset the alarms.

** This alarm display appears only within the range of 30 W to 1 kW.