Calculating the regenerative power capacity, Servo amplifiers with capacities of 400 w or less, Servo amplifiers capacities of 0.5 kw to 5.0 kw – Yaskawa FSP Amplifier User Manual

Page 141

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-74

5.6.2. Calculating the Regenerative Power Capacity

„

Simple Calculation Method

When driving a servomotor normally along the horizontal axis, check the
external regenerative resistor requirements using the calculation method
shown below.

Servo Amplifiers with Capacities of 400 W or Less

Servo amplifiers with capacities of 400 W or less do not have built-in
regenerative resistors. The energy that can be absorbed by capacitors is
shown in the following table. If the rotational energy in the servo system
exceeds these values, then connect a regenerative resistor externally.

Voltage

Applicable Servo

Amplifiers

Regenerative Energy

that Can Be Processed

(Joules)

Comments

FSP-A3B* 7.8

100 V

FSP-A5B* to FSP-02B*

15.7

Value when the input voltage
is 100 VAC

FSP-A3A*, FSP-A5A*

18.5

200 V

FSP-01A* to -04A*

37.1

Value when the input voltage
is 200 VAC

Calculate the rotational energy in the servo system using the following
equation:

E

S

=

( )

12566

N

x

J

2

M

Joules

Where: J = J

M

+ J

L

J

M

: Servomotor rotor inertia (kg·m

2

) (oz·in·s

2

)

J

L

: Motor axis conversion load inertia (kg·m

2

) (oz·in·s

2

)

N

M

: Rotation speed of the servomotor (rpm)

Servo Amplifiers Capacities of 0.5 kW to 5.0 kW

Servo amplifiers with capacities of 500 W to 5 kW have built-in
regenerative resistors. The allowable frequencies for just the servomotor
during acceleration/deceleration operation, in the run cycle from 0 Æ
maximum rotation speed Æ 0, are summarized in the following table.
Convert the data into the values obtained with actual rotation speed used
and load inertia to determine whether an external regenerative resistor is
needed.

Advertising