Servo Amplifier Capacity of 0.5 kW to 3.0 kW

Servomotors with a capacity of 500 W to 3 kW have built-in regenerative
resistors. The allowable frequencies for just the servomotor during
acceleration/deceleration operation, in the run cycle from 0 Æ maximum
rotation speed Æ 0, are summarized in the following table.
Convert the data into the values obtained with actual rotation speed used
and load inertia to determine whether an external regenerative resistor is
needed.

Series

Allowable Frequencies in Regeneration Mode (r/min)

Voltage

Capacity

Symbol

03

05

08

09

10

13

15

20

30 40 44 50

SGMAH-‰A

— — 89 — — — — — — — — —

SGMPH-‰A

— — 29 — — — 17 — — — — —

SGMGH-‰A

34 — 13 — 10 — 12 8 — 11 —

200 V

SGMSH-‰A

— — — — 39 — 31 48 20 29 — 22

SGMGH-‰D

42 — 15 — 10 — 12 8 — 11 —

SGMSH-‰D

— — — — 47 — 31 48 20 29 — 22

400 V

SGMUH-‰D

— — — — 27 — 19 — 13 19 — —

Operating Conditions for Allowable Regenerative
Frequency Calculation

Use the following equation to calculate the allowable frequency for
regeneration mode operation.

Allowable frequency =

n)

(1

only

servomotor

for

frequency

Allowable

+

x

2

used

speed

Rotation

speed

rotation

.

Max

⎟⎟

⎜⎜

Minute

Cycles

Where: n = J

L

/J

M

J

L

: Motor axis conversion load inertia [oz·in·s

2

(kg·m

2

)]

J

M

: Servomotor rotary inertia [oz·in·s

2

(kg·m

2

)]

Advertising